We wish you peaceful holidays and a successful start into the new year. We are among the winners of the Industrie 4. In a short video, our product manager Eduard Kirstgen introduces you to the different apps from the software module "Material" and describes their advantages.
Based on the information of the Material Locator and the order planning, various specialized Material Manager Apps are offered.
Listen in! See the first fully autonomous line! We will show you how the entire material handling, i. PCB and magazine handling, handling of component reels for the assembly process and handling of consumables for the printing process in your SMT line of the future can be done completely without operators. We can proudly announce that we have reached third place at the "Industrie 4. The Industrie 4. Our overall solution offers smart hardware and software solutions for monitoring and controlling autonomous material flows on the entire shopfloor.
One of the most important trade fairs for electronics manufacturing has now come to an end. We would like to thank you very much for your visit at our booth. We were very pleased to see old acquaintances again and to make new contacts. Despite the current restrictions due to the corona virus, we can draw a positive summary from the fair. Our team is already looking forward to the exciting future projects. Get to know us personally! We look forward to welcoming you to one of our events.
The entire line is completely independently adapted to the newly inserted product. Company The ASYS Group is a global technology company and leading supplier of machines for the electronics, energy and life science industries.
Services With us, you are always in competent hands - be it for maintenance, training or process support. News Webinars Events Productronica Career Are you looking for an employer where you are involved in exciting, future-oriented projects and where, in addition to your performance, you also count as a person? Contact If you would like to receive current information about our products and services or if you would like one of our employees to contact you, please fill out our contact form with your company address.
Contact form Contact Finder Locations. Do you have any questions? Find your local contact with our Contact Finder. Downloads Rest Assured We've Got It Covered.
Fivesite Guided Creative. Select Direct to parallel port and choose the parallel port your printer is connected from the pull down menu. The third option is to create a bitmap with your data. A bitmap showing a printing preview opens up. Serial printing simulation You may capture your data to a text file vrsimser. Please refer to 5. The second option is to direct the data to a com port. This option might be useful to send data to a different PC.
Choose an option for serial and parallel printing. Confirm your choice by pressing OK. The program is now set to your convenience. After the next measurement the data will be processed printed, save to file, etc. Use the View BMP option from the menu Special to view a previously created bitmap simulated printout. You are able to create plate data for simulation purposes. This data will be used for simulated measurements.
Open the Special menu in the top left corner of the Connect Plus window and select Edit plate data. A Plate data window appears which shows a microplate matrix. You can navigate through the wells with the Tab-key to the right and with the combination of Tab and Shift to the left.
Use the Up- and Down- Keys ,. To enter a value select the respective well and type in the desired value. Load the plate data to the program as described above. Set the serial printing simulation in printing options to capture to file vrsimser. Recall the plate data results and press F3 Print OD if you need the raw data only or F4 - Process to get the processed dates. Either way the data of this plate is now stored in vrsimser. To import the data to other programs please follow the instructions from the specific software.
Open the folder which contains the file vrsimser. Follow the instructions on the screen to import the plate data correctly to Excel. The EXPERT Plus has the great feature that you are able to print your data directly from the instrument - without connecting it to a computer. You may choose from a wide range of printers.
See 4. You can also print all stored plate data. Just choose Recall Plate data from the main menu and select the data you would like to print. You may either print the absorption values F3 or the processed data F4. If you dont have a printer connected to the instrument you can print the data with the printer connected to your computer. All data from the instrument can be uploaded to your computer with Connect Plus.
You are able to print all data stored in Connect Plus. All it takes are a few steps:. Measure the plate with a method of your choice. If no printer is connected you have to choose Non for output. Choose Recall Plate data if you wish to view your data on the screen.
You can also see which method has been used with your plate. Open the Connect Plus software and make sure the right method for your plate date is available. If the method is not stored on the computer you have to download it from the reader and update the simulation with the method first. Next download the plate data from the instrument to your PC. Before the next step set your printer in printing options: Select Special and Printing options Choose Direct to parallel port and the parallel port to which your standard Windows printer is connected.
Confirm with OK. Select the plate you would like to print and press enter of select. You may either just print the OD values only F3 or the processed data F4. The example on the next page shows a typical printout of a screening test with most the calculation options selected. The header lines are showing the plate ID, the used method, the measurement data and time and the filter s used for the measurement.
The next line indicates if the test is valid or not. In case of an invalid test the condition not met will be indicated too. The line after can be used to record lot numbers and expiration date of the reagent kit as well as the operators name. The legend line indicates the content and order of the results in the plate matrix. The line after the legend shows the threshold limits. It is followed by the measured and calculated data in a plate matrix format. This is followed by statistical information about the controls as well as information about the validity of the assay.
This chapter gives the instructions on how to maintain, clean and disinfect the Expert Plus. This instrument is a precision instrument and requires regular cleaning to ensure the continued precision. Liquid Spills. Regular cleaning. The housing of the instrument should be cleaned regularly with a mild household-cleaning agent.
To avoid risk of fire, replace fuses only with same type and rating. Switch off the instrument and unplug the power cord. Open the plastic cover of the fuse compartment, by inserting a screwdriver into the slot at the left side of the cover and pushing the cover out. Pull the fuse holder away from the instrument. Replace the fuses only with the same type and rating.
Ensure that the fuses have the correct rating: T 3. Reconnect the power cord and switch the instrument on. To replace one or more of these filters, please perform the following procedure: 1. Switch off the instrument. Open the filter compartment cover plate at the right side of the instrument backwards. Rotate the filter wheel, until the required filter or filter position is at the front. The filter position one is marked with a yellow sticker. Filter position two is located below the filter one.
Pull the filter, which is to be changed, out of the filter wheel. Carefully insert the 'new' filter in to the filter wheel. Carefully hold the filter only by the edges to avoid any fingerprints on the filters. Close the filter compartment cover. Switch the instrument on. After changing a filter, a calibration run is required.
Please see 4. If an interference filter is dirty it needs to be cleaned. For the cleaning procedure you need low-lint cotton-tipped swabs and a lens cleaning solution or reagent-grade isopropyl alcohol. First blow off dust and dirt with pressurized gas.
Apply a few drops of the cleaner on both sides of the filter and wipe-off the dirt with the cotton swabs. Allow the cleaner to evaporate and then visually check the filter surface for streaks or spots. If there are any repeat the procedure. When streaks or spots are visible which cannot be removed by the procedure as described above most probably they are inside the filter. In such a case the filter must be replaced. Note: Interference filters do have a limited lifetime of a few years, depending on the humidity and ambient temperature.
Under tropical conditions a filter may get unusable within less than two years. All parts of the instrument that come into contact with patient sera or positive controls must be treated as potentially infectious.
It is very important that the instrument is thoroughly disinfected before it is removed from the Laboratory or any servicing is performed on it. If the laboratory has no specific disinfecting procedure, the following procedure should be used to disinfect the instrument. The instrument should be disinfected using a suitable disinfecting solution. Disconnect the instrument from the mains power supply.
Disconnect the instrument from the computer. Carefully wipe all the outside surfaces of the instrument and the plate support area with a wad of cotton wool that has been soaked in the disinfecting solution. Place the instrument in to a large plastic bag. Place a wad of cotton wool that has been soaked in the disinfecting solution in to the plastic bag. Ensure that the wad is not touching the instrument.
Close and seal the plastic bag. Leave the instrument to stand in the plastic bag for at least 24 hours. Repeat the disinfecting procedure on any accessories that are also being moved or returned. Open navigation menu. Close suggestions Search Search. User Settings. Skip carousel. Carousel Previous. Carousel Next. What is Scribd? Explore Ebooks. Bestsellers Editors' Picks All Ebooks. Explore Audiobooks. Bestsellers Editors' Picks All audiobooks. Explore Magazines.
Editors' Picks All magazines. Explore Podcasts All podcasts.
0コメント